| General information | | | | | |
| Product type designation | DI 16x24VDC HF | DI 32x24VDC HF | DI 16x24VDC SRC BA | DI 16x230VAC BA | DI 16x24 ... 125VUC HF |
| Product function | | | | | |
| | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
| Engineering with | | | | | |
| | V13 SP1 / - | V13 SP1 / - | V12 / V12 | V12 / V12 | V13 SP1 / - |
| | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - |
| | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 |
| | V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - |
| Operating mode | | | | | |
| | Yes | Yes | Yes | Yes | Yes |
| | Yes | Yes | No | No | No |
| | No | | | | No |
| | Yes | Yes | Yes | Yes | Yes |
| Supply voltage | | | | | |
| Type of supply voltage | DC | DC | DC | | |
| Rated value (DC) | 24 V | 24 V | | | |
| Reverse polarity protection | Yes | Yes | | | |
| Digital inputs | | | | | |
| Number of digital inputs | 16 | 32 | 16 | 16 | 16 |
| Digital inputs, parameterizable | Yes | Yes | No | No | Yes |
| Source/sink input | P-reading | P-reading | m-reading | P-reading | Yes |
| Input characteristic curve in ordance with IEC 61131, type 1 | | | | Yes | |
| Input characteristic curve in ordance with IEC 61131, type 3 | Yes | Yes | Yes | | Yes; at 24 V DC |
| Digital input functions, parameterizable | | | | | |
| | Yes | Yes | | | |
| | Yes | Yes | | | |
| | | | | | |
| | 2 | 2 | | | |
| | 1 kHz | 1 kHz | | | |
| | 32 bit | 32 bit | | | |
| | Up | Up | | | |
| Input voltage | | | | | |
| | DC | DC | DC | AC | AC/DC |
| | 24 V | 24 V | 24 V | | 24 V; 48 V, 125 V |
| | | | | 230 V; 120/230V AC, 50/60 Hz | 24 V; 48 V, 125 V (50 - 60 Hz) |
| | -30 to +5V | -30 to +5V | -5 to +30V | 0V AC to 40V AC | -5 ... +5 V |
| | +11 to +30V | +11 to +30V | -11 to -30V | 79V AC to 264V AC | +11 V DC to +146 V DC |
| Input current | | | | | |
| | 2.5 mA | 2.5 mA | 4.5 mA | 11 mA; At 230 V AC and 5.5 mA at 120 V AC | 3 mA; at 24 V DC |
| Input delay (for rated value of input voltage) | | | | | |
| for standard inputs | | | | | |
| | Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | No | No | Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms parameterizable with DC, 20 ms fixed with AC |
| for interrupt inputs | | | | | |
| | Yes | Yes | No | No | Yes |
| for counter/technological functions | | | | | |
| | Yes | Yes | No | No | No |
| Cable length | | | | | |
| | 1 000 m | 1 000 m | 1 000 m | 1 000 m | 1 000 m |
| | 600 m | 600 m | 600 m | 600 m | 600 m |
| Encoder | | | | | |
| Connectable encoders | | | | | |
| | Yes | Yes | Yes | Yes | Yes |
| | 1.5 mA | 1.5 mA | 1.5 mA | 2 mA | 1.5 mA |
| Isochron mode | | | | | |
| Isochron operation (application synchronized up to terminal) | Yes | Yes | No | No | No |
| Filtering and processing time (TCI), min. | 80 µs; At 50 μs filter time | 80 µs; At 50 μs filter time | | | |
| cycle time (TDP), min. | 250 µs | 250 µs | | | |
| Interrupts/diagnostics/sta information | | | | | |
| Diagnostics function | Yes | Yes | No | No | Yes |
| Alarms | | | | | |
| | Yes | Yes | No | No | Yes |
| | Yes | Yes | No | No | Yes |
| Diagnostic messages | | | | | |
| | Yes | Yes | No | No | No |
| | Yes; to I < 350 µA | Yes; to I < 350 µA | No | No | Yes; To I < 550 µA |
| | No | No | No | No | No |
| Diagnostics indication LED | | | | | |
| | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED |
| | Yes; Green LED | Yes; Green LED | No | No | No |
| | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| | Yes; Red LED | Yes; Red LED | No | No | Yes; Red LED |
| | Yes; Red LED | Yes; Red LED | No | Yes; Red LED | Yes; Red LED |
| Potential separation | | | | | |
| Potential separation channels | | | | | |
| | Yes | Yes | Yes | Yes | Yes |
| Isolation | | | | | |
| Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 3 100 V DC | 2 000 V DC |
| Standards, approvals, certificates | | | | | |
| Suitable for safety functions | No | No | No | No | No |
| Ambient conditions | | | | | |
| Ambient temperature during operation | | | | | |
| | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C |
| | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| | 40 °C | 40 °C | 40 °C | 40 °C | 40 °C |
| Decentralized operation | | | | | |
| Prioritized startup | Yes | Yes | Yes | Yes | Yes |
| Dimensions | | | | | |
| Width | 35 mm | 35 mm | 35 mm | 35 mm | 35 mm |
| Height | 147 mm | 147 mm | 147 mm | 147 mm | 147 mm |
| Depth | 129 mm | 129 mm | 129 mm | 129 mm | 129 mm |
| Weights | | | | | |
| Weight, approx. | 240 g | 260 g | 230 g | 300 g | 240 g |